Sub-Cooler Technical Information


General Description

Carbo Tech sub-coolers consist of a high quality condensing unit coupled to a balanced heat exchanger. When properly sized and installed, they will remove much of the heat developed in loop systems. All units utilize R-404A (HP-62) environmentally safe refrigerant, and are factory tested for proper operation.


Specifications

  1. Copeland semi-hermetic condensing unit.
  2. R-404A environmentally safe refrigerant.
  3. Balanced heat exchanger rated at 450 PSIG.
  4. 350 PSIG relief valve provided.
  5. Pressure switch provided.
  6. NEMA 3R electrical enclosure.
  7. Aluminum angle framework, with prepainted white aluminum cover.

Capacities

Model HP Rating at -20 degree evap.
CT-SC3 3 14,500 BTU's per hour
CT-SC6 6 28,300 BTU's per hour
CT-SC10 10 53,600 BTU's per hour
CT-SC15 15 70,500 BTU's per hour

Back to Carbo Tech Sub-cooler Bulletin

828 Hwy. 11 SE - P.O. Box 1938 - Monroe, GA 30655
Phone - 770/267-8821 - FAX - 770/267-7286
E-Mail - info@carbotech.com